Anode Splice Encapsulation Shrink Sleeve Kit Installation Guide

Anode Splice Encapsulation Shrink Sleeve Kit Install Instructions



Preparing the Cable:












  Install connector. Note maximum length of stripped wire leads. Wipe off excess contact compound.


Position tie wrap(s) as shown. Two are required for "H" connections. Note: 1/8 inch gap produced for adhesive encapsulation.



Wrap insulation strip or tape centered on connection. If required, heat strip end slightly to tack in place.



Position Sleeve:

 








Position sleeve closure over main cable run.














Slide channel onto sleeve rails.










Channel ends should extend evenly beyond ends of sleeve.



Heat-shrink assembly:











Using yellow tip of torch flame, apply heat in a uniform back and forth motion, giving special emphasis to rail/channel area.











Apply heat until all indicator paint changes color. Adhesive will extrude from sleeve ends












A few minutes cooling may be required for complete encapsulation to occur between cables.